civil engineering practical works 2020,civil engineering practical knowledge,practical knowledge of civil site engineer,practical knowledge of construction,civil engineer must know pdf,civil engineering fundamentals 2020,things a civil engineering student must know,general knowledge in civil engineering,civil engineering site knowledge

Thursday, May 28, 2020

[30] Basic knowledge For Every Site Engineer :-

 In civil engineering you should be learn technical points & Terms , Which is used on site !
This terms are playing a important rule for a fresher Civil Engineer.

Basic knowledge

  1. Lintel Thickness Should be -15 cm.
  2. Minimum diameter of main bar & distribution bar in the Slab - 8 mm.
  3. Maximum diameter of main bar & distribution bar is in the slab - 1/8 of slab thickness.
  4. DPC ( damp proof coarse ) thickness should be - 2.5 cm. 
  5. Minimum Plinth height should be  - 45 cm.
  6. Maximum chair spacing should be - 1 meter
  7. Minimum diameter reinforcement for Dowel should be - 12 mm
  8. Diameter tolerance for cubes should be - ± 2 mm.
  9. Maximum water observation for Bricks - 15 % - 20 %.
  10. Building Height should be minimum(floor level - roof level) - 3.15 meter .
  11. In stair case Riser height should be - 15 cm .
  12. Compressive strength of bricks should be minimum - 3.5 n/㎟ .
  13. Density of Bricks - 1600 - 1920 kg/㎥.
  14. Minimum Thickness of Slab - 125 mm .

Clear Cover To Main Reinforcement -:

  • Cover is Basically Two Types -
  1. Clear cover .
  2. Effective cover .

Clear Cover what is the meaning of Clear cover & Effective cover?

  1. Minimum distance between Reinforcement to the outer surface of concrete , Is called Clear cover . 
  2. Minimum distance between Mid-Reinforcement to the outer surface of concrete , Is called Effective cover.
Use of  cover :-

  • To provide protection to reinforcement from corrosion.
  • To provide fire resistance to Reinforcement.

Different types of Reinforcement & it's Clear cover 

    Effective Cover
  1. Footings : 50 mm
  2. Raft Foundation(top) : 50 mm
  3. Raft Foundation (Bottom) : 75 mm
  4. Raft Foundation (Side) : 75 mm
  5. Beam : 25 mm
  6. Strap Beam : 50 mm
  7. Column : 40 mm
  8. Slab : 20 mm
  9. Flat slab : 20 mm
  10. Stair case : 20 mm
  11. Retaining wall : 20 - 25 mm
  12. Water Retaining Structures : 20-30 mm